{"id":8522,"date":"2018-02-12T07:52:51","date_gmt":"2018-02-12T07:52:51","guid":{"rendered":"https:\/\/www.tarluz.com\/?p=8522"},"modified":"2018-02-12T08:48:51","modified_gmt":"2018-02-12T08:48:51","slug":"multimode-om1-om2-om3-om4-om5-single-mode-os1-os2-fiber","status":"publish","type":"post","link":"https:\/\/www.tarluz.com\/ar\/data-center\/multimode-om1-om2-om3-om4-om5-single-mode-os1-os2-fiber\/","title":{"rendered":"Multimode (OM1, OM2, OM3, OM4, OM5) and Single Mode (OS1, OS2) Fiber"},"content":{"rendered":"<p>What are OM and OS type fiber optic cables?<br \/>\nIn ANSI\/TIA-568.3-D, the TIA adopted the nomenclature for fiber found in the international standard ISO\/IEC 11801. The multimode fiber is prefixed with \u201cOM\u201d and the singlemode mode \u201cOS\u201d.<\/p>\n<p>The new designation in ANSI\/TIA-568.3-D should alleviate some of the confusion associated with application support distance issues. Each \u201cOM\u201d has a minimum Modal Bandwidth (MBW) requirement.<\/p>\n<p>Bandwidth and attenuation comparison between different OM fiber optic cables<\/p>\n<table border=\"1\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody align=\"center\">\n<tr align=\"center\">\n<td colspan=\"3\">Multimode Fiber<\/td>\n<td colspan=\"2\">Overfilled launch bandwidth (MHz.km)<\/td>\n<td>Laser Launch<\/td>\n<td colspan=\"2\">Attenuations (dB\/km)<\/td>\n<\/tr>\n<tr align=\"center\">\n<td>Fiber Type<\/td>\n<td>TIA Fiber Standard<\/td>\n<td>Core diameter (um)<\/td>\n<td>850 nm<\/td>\n<td>1300 nm<\/td>\n<td>850 nm<\/td>\n<td>850nm<\/td>\n<td>1300nm<\/td>\n<\/tr>\n<tr align=\"center\">\n<td><strong>OM1<\/strong><\/td>\n<td>492-AAAA<\/td>\n<td>62.5<\/td>\n<td>200<\/td>\n<td>500<\/td>\n<td>Not specified<\/td>\n<td>3.5<\/td>\n<td>1.5<\/td>\n<\/tr>\n<tr align=\"center\">\n<td><strong>OM2<\/strong><\/td>\n<td>492-AAAB<\/td>\n<td>50<\/td>\n<td>500<\/td>\n<td>500<\/td>\n<td>Not specified<\/td>\n<td>3.5<\/td>\n<td>1.5<\/td>\n<\/tr>\n<tr align=\"center\">\n<td><strong>OM3<\/strong><\/td>\n<td>492-AAAC<\/td>\n<td>50<\/td>\n<td>1500<\/td>\n<td>500<\/td>\n<td>2,000<\/td>\n<td>2.3<\/td>\n<td>0.6<\/td>\n<\/tr>\n<tr align=\"center\">\n<td><strong>OM4<\/strong><\/td>\n<td>492-AAAD<\/td>\n<td>50<\/td>\n<td>3500<\/td>\n<td>500<\/td>\n<td>4,700<\/td>\n<td>2.3<\/td>\n<td>0.6<\/td>\n<\/tr>\n<tr align=\"center\">\n<td><strong>OM5<\/strong><\/td>\n<td>492-AAAE<\/td>\n<td>50<\/td>\n<td>3500<\/td>\n<td>500<\/td>\n<td>4,700<\/td>\n<td>2.4<\/td>\n<td>0.6<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Attenuation refered to YOFC Multimode Fiber.<\/p>\n<p>Maximum channel length comparison between different OM fiber optic cables<\/p>\n<table border=\"1\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr align=\"center\">\n<td rowspan=\"2\">\u00a0Fiber Mode<\/td>\n<td rowspan=\"2\">100BASE<\/td>\n<td colspan=\"2\">1000BASE<\/td>\n<td colspan=\"2\">10GBASE<\/td>\n<td rowspan=\"2\">40GBASE<\/td>\n<td rowspan=\"2\">100GBASE<\/td>\n<\/tr>\n<tr align=\"center\">\n<td>850nm<\/td>\n<td>1300nm<\/td>\n<td>850nm<\/td>\n<td>1300nm<\/td>\n<\/tr>\n<tr align=\"center\">\n<td>OM1<\/td>\n<td>up to 2000m<\/td>\n<td>275m<\/td>\n<td>550m<\/td>\n<td>33m<\/td>\n<td>up to 300m<\/td>\n<td>Not specified<\/td>\n<td>Not specified<\/td>\n<\/tr>\n<tr align=\"center\">\n<td>OM2<\/td>\n<td>up to 2000m<\/td>\n<td>550m<\/td>\n<td>550m<\/td>\n<td>82m<\/td>\n<td>up to 300m<\/td>\n<td>Not specified<\/td>\n<td>Not specified<\/td>\n<\/tr>\n<tr align=\"center\">\n<td>OM3<\/td>\n<td>up to 2000m<\/td>\n<td>550m<\/td>\n<td>550m<\/td>\n<td>300m<\/td>\n<td>up to 300m<\/td>\n<td>100m<\/td>\n<td>100m<\/td>\n<\/tr>\n<tr align=\"center\">\n<td>OM4<\/td>\n<td>up to 2000m<\/td>\n<td>1000m<\/td>\n<td>550m<\/td>\n<td>550m<\/td>\n<td>400m*<\/td>\n<td>150m<\/td>\n<td>150m<\/td>\n<\/tr>\n<tr align=\"center\">\n<td>OM5<\/td>\n<td>up to 2000m<\/td>\n<td>Not specified<\/td>\n<td>Not specified<\/td>\n<td>Not specified<\/td>\n<td>400m*<\/td>\n<td>150m<\/td>\n<td>150m<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Attenuation comparison between different OS fiber optic cables<\/p>\n<table border=\"1\" cellpadding=\"0\" cellspacing=\"0\" width=\"100%\">\n<tbody>\n<tr>\n<td  >\u00a0<\/td>\n<td  >1310 nm<\/td>\n<td  >1383nm<\/td>\n<td  >1550 nm<\/td>\n<\/tr>\n<tr>\n<td  >OS1(EN50173-1:Ed.2: 2010)\n      <\/td>\n<td  >1.0 dB\/km<\/td>\n<td  >1.0 dB\/km<\/td>\n<td  >1.0 dB\/km<\/td>\n<\/tr>\n<tr>\n<td  >OS2(EN50173-1:Ed.2: 2010)<\/td>\n<td  >0.4 dB\/km<\/td>\n<td  >0.4 dB\/km<\/td>\n<td  >0.4 dB\/km<\/td>\n<\/tr>\n<tr>\n<td  >OS1(ISO\/IEC11801Ed.2.2:2010)<\/td>\n<td  >1.0 dB\/km<\/td>\n<td  >Not specified<\/td>\n<td  >1.0 dB\/km<\/td>\n<\/tr>\n<tr>\n<td >OS2(ISO\/IEC11801Ed.2.2: 2010)<\/td>\n<td >0.4 dB\/km<\/td>\n<td >0.4 dB\/km<\/td>\n<td >0.4 dB\/km<\/td>\n<\/tr>\n<tr>\n<td  >OS2(ISO\/IEC24702: 2006)<\/td>\n<td >0.4 dB\/km<\/td>\n<td >0.4 dB\/km<\/td>\n<td >0.4 dB\/km<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>What are OM and OS type fiber optic cables? In ANSI\/TIA-568.3-D, the TIA adopted the nomenclature for fiber found in the international standard ISO\/IEC 11801. The multimode fiber is prefixed with \u201cOM\u201d and the singlemode mode \u201cOS\u201d. The new designation in ANSI\/TIA-568.3-D should alleviate some of the confusion associated with application support distance issues. Each [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":4888,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[399,1001],"tags":[],"class_list":["post-8522","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-data-center","category-fiber-optic-cable"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v23.3 (Yoast SEO v27.5) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Multimode (OM1, OM2, OM3, OM4, OM5) and Single Mode (OS1, OS2) Fiber - TARLUZ - FIBER OPTIC SUPPLIERS<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.tarluz.com\/ar\/data-center\/multimode-om1-om2-om3-om4-om5-single-mode-os1-os2-fiber\/\" \/>\n<meta property=\"og:locale\" content=\"ar_AR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Multimode (OM1, OM2, OM3, OM4, OM5) and Single Mode (OS1, OS2) Fiber\" \/>\n<meta property=\"og:description\" content=\"What are OM and OS type fiber optic cables? In ANSI\/TIA-568.3-D, the TIA adopted the nomenclature for fiber found in the international standard ISO\/IEC 11801. The multimode fiber is prefixed with \u201cOM\u201d and the singlemode mode \u201cOS\u201d. The new designation in ANSI\/TIA-568.3-D should alleviate some of the confusion associated with application support distance issues. Each [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.tarluz.com\/ar\/data-center\/multimode-om1-om2-om3-om4-om5-single-mode-os1-os2-fiber\/\" \/>\n<meta property=\"og:site_name\" content=\"TARLUZ - FIBER OPTIC SUPPLIERS\" \/>\n<meta property=\"article:published_time\" content=\"2018-02-12T07:52:51+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2018-02-12T08:48:51+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.tarluz.com\/wp-content\/uploads\/2017\/04\/OM5-Fiber-2.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"667\" \/>\n\t<meta property=\"og:image:height\" content=\"400\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"TARLUZ.COM\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u0643\u064f\u062a\u0628 \u0628\u0648\u0627\u0633\u0637\u0629\" \/>\n\t<meta name=\"twitter:data1\" content=\"TARLUZ.COM\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u0648\u0642\u062a \u0627\u0644\u0642\u0631\u0627\u0621\u0629 \u0627\u0644\u0645\u064f\u0642\u062f\u0651\u0631\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 \u062f\u0642\u064a\u0642\u0629\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.tarluz.com\\\/ar\\\/data-center\\\/multimode-om1-om2-om3-om4-om5-single-mode-os1-os2-fiber\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.tarluz.com\\\/ar\\\/data-center\\\/multimode-om1-om2-om3-om4-om5-single-mode-os1-os2-fiber\\\/\"},\"author\":{\"name\":\"TARLUZ.COM\",\"@id\":\"https:\\\/\\\/www.tarluz.com\\\/ar\\\/#\\\/schema\\\/person\\\/5740f1b7210de5d651317604459f2fb1\"},\"headline\":\"Multimode (OM1, OM2, OM3, OM4, OM5) and Single Mode (OS1, OS2) Fiber\",\"datePublished\":\"2018-02-12T07:52:51+00:00\",\"dateModified\":\"2018-02-12T08:48:51+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.tarluz.com\\\/ar\\\/data-center\\\/multimode-om1-om2-om3-om4-om5-single-mode-os1-os2-fiber\\\/\"},\"wordCount\":278,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.tarluz.com\\\/ar\\\/data-center\\\/multimode-om1-om2-om3-om4-om5-single-mode-os1-os2-fiber\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.tarluz.com\\\/wp-content\\\/uploads\\\/2017\\\/04\\\/OM5-Fiber-2.jpg\",\"articleSection\":[\"Data Center\",\"Fiber Optic Cable\"],\"inLanguage\":\"ar\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.tarluz.com\\\/ar\\\/data-center\\\/multimode-om1-om2-om3-om4-om5-single-mode-os1-os2-fiber\\\/\",\"url\":\"https:\\\/\\\/www.tarluz.com\\\/ar\\\/data-center\\\/multimode-om1-om2-om3-om4-om5-single-mode-os1-os2-fiber\\\/\",\"name\":\"Multimode (OM1, OM2, OM3, OM4, OM5) and Single Mode (OS1, OS2) Fiber - TARLUZ - FIBER OPTIC SUPPLIERS\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.tarluz.com\\\/ar\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.tarluz.com\\\/ar\\\/data-center\\\/multimode-om1-om2-om3-om4-om5-single-mode-os1-os2-fiber\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.tarluz.com\\\/ar\\\/data-center\\\/multimode-om1-om2-om3-om4-om5-single-mode-os1-os2-fiber\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.tarluz.com\\\/wp-content\\\/uploads\\\/2017\\\/04\\\/OM5-Fiber-2.jpg\",\"datePublished\":\"2018-02-12T07:52:51+00:00\",\"dateModified\":\"2018-02-12T08:48:51+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/www.tarluz.com\\\/ar\\\/#\\\/schema\\\/person\\\/5740f1b7210de5d651317604459f2fb1\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.tarluz.com\\\/ar\\\/data-center\\\/multimode-om1-om2-om3-om4-om5-single-mode-os1-os2-fiber\\\/#breadcrumb\"},\"inLanguage\":\"ar\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.tarluz.com\\\/ar\\\/data-center\\\/multimode-om1-om2-om3-om4-om5-single-mode-os1-os2-fiber\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ar\",\"@id\":\"https:\\\/\\\/www.tarluz.com\\\/ar\\\/data-center\\\/multimode-om1-om2-om3-om4-om5-single-mode-os1-os2-fiber\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.tarluz.com\\\/wp-content\\\/uploads\\\/2017\\\/04\\\/OM5-Fiber-2.jpg\",\"contentUrl\":\"https:\\\/\\\/www.tarluz.com\\\/wp-content\\\/uploads\\\/2017\\\/04\\\/OM5-Fiber-2.jpg\",\"width\":667,\"height\":400},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.tarluz.com\\\/ar\\\/data-center\\\/multimode-om1-om2-om3-om4-om5-single-mode-os1-os2-fiber\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.tarluz.com\\\/ar\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Multimode (OM1, OM2, OM3, OM4, OM5) and Single Mode (OS1, OS2) Fiber\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.tarluz.com\\\/ar\\\/#website\",\"url\":\"https:\\\/\\\/www.tarluz.com\\\/ar\\\/\",\"name\":\"TARLUZ - FIBER OPTIC SUPPLIERS\",\"description\":\"DEDICATED IN FIBER OPTIC INDUSTRY\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.tarluz.com\\\/ar\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ar\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.tarluz.com\\\/ar\\\/#\\\/schema\\\/person\\\/5740f1b7210de5d651317604459f2fb1\",\"name\":\"TARLUZ.COM\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ar\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/6e1d411095ca6ac0a50a32b0e09d4e99f1d22d747cb3e84f95fe301bdc28d113?s=96&d=blank&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/6e1d411095ca6ac0a50a32b0e09d4e99f1d22d747cb3e84f95fe301bdc28d113?s=96&d=blank&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/6e1d411095ca6ac0a50a32b0e09d4e99f1d22d747cb3e84f95fe301bdc28d113?s=96&d=blank&r=g\",\"caption\":\"TARLUZ.COM\"},\"url\":\"https:\\\/\\\/www.tarluz.com\\\/ar\\\/author\\\/admin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Multimode (OM1, OM2, OM3, OM4, OM5) and Single Mode (OS1, OS2) Fiber - TARLUZ - FIBER OPTIC SUPPLIERS","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.tarluz.com\/ar\/data-center\/multimode-om1-om2-om3-om4-om5-single-mode-os1-os2-fiber\/","og_locale":"ar_AR","og_type":"article","og_title":"Multimode (OM1, OM2, OM3, OM4, OM5) and Single Mode (OS1, OS2) Fiber","og_description":"What are OM and OS type fiber optic cables? In ANSI\/TIA-568.3-D, the TIA adopted the nomenclature for fiber found in the international standard ISO\/IEC 11801. The multimode fiber is prefixed with \u201cOM\u201d and the singlemode mode \u201cOS\u201d. The new designation in ANSI\/TIA-568.3-D should alleviate some of the confusion associated with application support distance issues. Each [&hellip;]","og_url":"https:\/\/www.tarluz.com\/ar\/data-center\/multimode-om1-om2-om3-om4-om5-single-mode-os1-os2-fiber\/","og_site_name":"TARLUZ - FIBER OPTIC SUPPLIERS","article_published_time":"2018-02-12T07:52:51+00:00","article_modified_time":"2018-02-12T08:48:51+00:00","og_image":[{"width":667,"height":400,"url":"https:\/\/www.tarluz.com\/wp-content\/uploads\/2017\/04\/OM5-Fiber-2.jpg","type":"image\/jpeg"}],"author":"TARLUZ.COM","twitter_card":"summary_large_image","twitter_misc":{"\u0643\u064f\u062a\u0628 \u0628\u0648\u0627\u0633\u0637\u0629":"TARLUZ.COM","\u0648\u0642\u062a \u0627\u0644\u0642\u0631\u0627\u0621\u0629 \u0627\u0644\u0645\u064f\u0642\u062f\u0651\u0631":"1 \u062f\u0642\u064a\u0642\u0629"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.tarluz.com\/ar\/data-center\/multimode-om1-om2-om3-om4-om5-single-mode-os1-os2-fiber\/#article","isPartOf":{"@id":"https:\/\/www.tarluz.com\/ar\/data-center\/multimode-om1-om2-om3-om4-om5-single-mode-os1-os2-fiber\/"},"author":{"name":"TARLUZ.COM","@id":"https:\/\/www.tarluz.com\/ar\/#\/schema\/person\/5740f1b7210de5d651317604459f2fb1"},"headline":"Multimode (OM1, OM2, OM3, OM4, OM5) and Single Mode (OS1, OS2) Fiber","datePublished":"2018-02-12T07:52:51+00:00","dateModified":"2018-02-12T08:48:51+00:00","mainEntityOfPage":{"@id":"https:\/\/www.tarluz.com\/ar\/data-center\/multimode-om1-om2-om3-om4-om5-single-mode-os1-os2-fiber\/"},"wordCount":278,"commentCount":0,"image":{"@id":"https:\/\/www.tarluz.com\/ar\/data-center\/multimode-om1-om2-om3-om4-om5-single-mode-os1-os2-fiber\/#primaryimage"},"thumbnailUrl":"https:\/\/www.tarluz.com\/wp-content\/uploads\/2017\/04\/OM5-Fiber-2.jpg","articleSection":["Data Center","Fiber Optic Cable"],"inLanguage":"ar"},{"@type":"WebPage","@id":"https:\/\/www.tarluz.com\/ar\/data-center\/multimode-om1-om2-om3-om4-om5-single-mode-os1-os2-fiber\/","url":"https:\/\/www.tarluz.com\/ar\/data-center\/multimode-om1-om2-om3-om4-om5-single-mode-os1-os2-fiber\/","name":"Multimode (OM1, OM2, OM3, OM4, OM5) and Single Mode (OS1, OS2) Fiber - TARLUZ - FIBER OPTIC SUPPLIERS","isPartOf":{"@id":"https:\/\/www.tarluz.com\/ar\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.tarluz.com\/ar\/data-center\/multimode-om1-om2-om3-om4-om5-single-mode-os1-os2-fiber\/#primaryimage"},"image":{"@id":"https:\/\/www.tarluz.com\/ar\/data-center\/multimode-om1-om2-om3-om4-om5-single-mode-os1-os2-fiber\/#primaryimage"},"thumbnailUrl":"https:\/\/www.tarluz.com\/wp-content\/uploads\/2017\/04\/OM5-Fiber-2.jpg","datePublished":"2018-02-12T07:52:51+00:00","dateModified":"2018-02-12T08:48:51+00:00","author":{"@id":"https:\/\/www.tarluz.com\/ar\/#\/schema\/person\/5740f1b7210de5d651317604459f2fb1"},"breadcrumb":{"@id":"https:\/\/www.tarluz.com\/ar\/data-center\/multimode-om1-om2-om3-om4-om5-single-mode-os1-os2-fiber\/#breadcrumb"},"inLanguage":"ar","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.tarluz.com\/ar\/data-center\/multimode-om1-om2-om3-om4-om5-single-mode-os1-os2-fiber\/"]}]},{"@type":"ImageObject","inLanguage":"ar","@id":"https:\/\/www.tarluz.com\/ar\/data-center\/multimode-om1-om2-om3-om4-om5-single-mode-os1-os2-fiber\/#primaryimage","url":"https:\/\/www.tarluz.com\/wp-content\/uploads\/2017\/04\/OM5-Fiber-2.jpg","contentUrl":"https:\/\/www.tarluz.com\/wp-content\/uploads\/2017\/04\/OM5-Fiber-2.jpg","width":667,"height":400},{"@type":"BreadcrumbList","@id":"https:\/\/www.tarluz.com\/ar\/data-center\/multimode-om1-om2-om3-om4-om5-single-mode-os1-os2-fiber\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.tarluz.com\/ar\/"},{"@type":"ListItem","position":2,"name":"Multimode (OM1, OM2, OM3, OM4, OM5) and Single Mode (OS1, OS2) Fiber"}]},{"@type":"WebSite","@id":"https:\/\/www.tarluz.com\/ar\/#website","url":"https:\/\/www.tarluz.com\/ar\/","name":"TARLUZ - FIBER OPTIC SUPPLIERS","description":"DEDICATED IN FIBER OPTIC INDUSTRY","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.tarluz.com\/ar\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ar"},{"@type":"Person","@id":"https:\/\/www.tarluz.com\/ar\/#\/schema\/person\/5740f1b7210de5d651317604459f2fb1","name":"TARLUZ.COM","image":{"@type":"ImageObject","inLanguage":"ar","@id":"https:\/\/secure.gravatar.com\/avatar\/6e1d411095ca6ac0a50a32b0e09d4e99f1d22d747cb3e84f95fe301bdc28d113?s=96&d=blank&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/6e1d411095ca6ac0a50a32b0e09d4e99f1d22d747cb3e84f95fe301bdc28d113?s=96&d=blank&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/6e1d411095ca6ac0a50a32b0e09d4e99f1d22d747cb3e84f95fe301bdc28d113?s=96&d=blank&r=g","caption":"TARLUZ.COM"},"url":"https:\/\/www.tarluz.com\/ar\/author\/admin\/"}]}},"_links":{"self":[{"href":"https:\/\/www.tarluz.com\/ar\/wp-json\/wp\/v2\/posts\/8522","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.tarluz.com\/ar\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.tarluz.com\/ar\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.tarluz.com\/ar\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.tarluz.com\/ar\/wp-json\/wp\/v2\/comments?post=8522"}],"version-history":[{"count":7,"href":"https:\/\/www.tarluz.com\/ar\/wp-json\/wp\/v2\/posts\/8522\/revisions"}],"predecessor-version":[{"id":8534,"href":"https:\/\/www.tarluz.com\/ar\/wp-json\/wp\/v2\/posts\/8522\/revisions\/8534"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.tarluz.com\/ar\/wp-json\/wp\/v2\/media\/4888"}],"wp:attachment":[{"href":"https:\/\/www.tarluz.com\/ar\/wp-json\/wp\/v2\/media?parent=8522"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.tarluz.com\/ar\/wp-json\/wp\/v2\/categories?post=8522"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.tarluz.com\/ar\/wp-json\/wp\/v2\/tags?post=8522"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}