{"id":8536,"date":"2018-02-22T08:00:14","date_gmt":"2018-02-22T08:00:14","guid":{"rendered":"https:\/\/www.tarluz.com\/?p=8536"},"modified":"2018-02-22T08:24:09","modified_gmt":"2018-02-22T08:24:09","slug":"introduction-non-contact-mpo-fiber-connectors","status":"publish","type":"post","link":"https:\/\/www.tarluz.com\/es\/data-center\/introduction-non-contact-mpo-fiber-connectors\/","title":{"rendered":"Introduction to  Non-contact MPO Fiber Connectors"},"content":{"rendered":"<p style=\"text-align: justify;\">The Non-Contact MPO fiber connector (NC-MPO) invented by Arrayed Fiberoptics, it might be the next generation multi-fiber optical connector for data center project, where there is no contact between fiber surfaces. There are two key elements in the NC-MPO connector, first, the fiber surface is recessed, and second, the fiber surface has an anti-reflection coating. It offers vastly improved optical performance and longevity.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-8546\" src=\"https:\/\/www.tarluz.com\/wp-content\/uploads\/2018\/02\/MPO-NC-MPO-Comparison.jpg\" alt=\"\" width=\"466\" height=\"453\" \/><\/p>\n<p><strong>Features<\/strong><\/p>\n<ul>\n<li>Low insertion loss: 0.06dBtypical;<\/li>\n<li>High return loss: &gt;70dB (single mode);<\/li>\n<li>Interchangeability: guaranteed connection between connectors;<\/li>\n<li>Good insertion loss repeatability: &lt;0.01dB; Not sensitive to dust; Long connector mating life: &gt;2,000 matings (10 times traditional MPO);<\/li>\n<li>NC-MPO can mate traditional MPO;<\/li>\n<li>Cost of production is comparable to traditional MPO connectors.<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p><strong>Specifications<\/strong><\/p>\n<table width=\"100%\">\n<tbody>\n<tr>\n<td width=\"30%\">Insertion Loss<\/td>\n<td width=\"70%\"><\/td>\n<\/tr>\n<tr>\n<td>Meain Value<\/td>\n<td>0.06dB<\/td>\n<\/tr>\n<tr>\n<td>Standard Deviation<\/td>\n<td>0.04dB<\/td>\n<\/tr>\n<tr>\n<td>97% distribution<\/td>\n<td>0.15dB<\/td>\n<\/tr>\n<tr>\n<td>Repeatability<\/td>\n<td>&lt;0.01dB<\/td>\n<\/tr>\n<tr>\n<td>Maximum Value<\/td>\n<td>0.19dB<\/td>\n<\/tr>\n<tr>\n<td>Minimum Value<\/td>\n<td>0.01dB<\/td>\n<\/tr>\n<tr>\n<td>Return Loss<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Mean Value<\/td>\n<td>80.1dB<\/td>\n<\/tr>\n<tr>\n<td>Maximum Value<\/td>\n<td>83.6dB<\/td>\n<\/tr>\n<tr>\n<td>Minimum Value<\/td>\n<td>73.4dB<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p><strong>Connector Detail<\/strong><\/p>\n<ul>\n<li>Connector Type: NC-MPO12, NC-MPO48<\/li>\n<li>Fiber type: SM, MM<\/li>\n<li>Polish angle: 0\u00ba, 8\u00ba<\/li>\n<li>AR coating wavelength band<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p>For more information, go to <a href=\"http:\/\/www.arrayedfiberoptics.com\/\" target=\"_blank\" rel=\"noopener\">Arrayed Fiberoptics Corp.<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The Non-Contact MPO fiber connector (NC-MPO) invented by Arrayed Fiberoptics, it might be the next generation multi-fiber optical connector for data center project, where there is no contact between fiber surfaces. There are two key elements in the NC-MPO connector, first, the fiber surface is recessed, and second, the fiber surface has an anti-reflection coating. [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":8547,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[399],"tags":[],"class_list":["post-8536","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-data-center"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v23.3 (Yoast SEO v27.4) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Introduction to Non-contact MPO Fiber Connectors - TARLUZ - FIBER OPTIC SUPPLIERS<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.tarluz.com\/es\/data-center\/introduction-non-contact-mpo-fiber-connectors\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Introduction to Non-contact MPO Fiber Connectors\" \/>\n<meta property=\"og:description\" content=\"The Non-Contact MPO fiber connector (NC-MPO) invented by Arrayed Fiberoptics, it might be the next generation multi-fiber optical connector for data center project, where there is no contact between fiber surfaces. There are two key elements in the NC-MPO connector, first, the fiber surface is recessed, and second, the fiber surface has an anti-reflection coating. [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.tarluz.com\/es\/data-center\/introduction-non-contact-mpo-fiber-connectors\/\" \/>\n<meta property=\"og:site_name\" content=\"TARLUZ - FIBER OPTIC SUPPLIERS\" \/>\n<meta property=\"article:published_time\" content=\"2018-02-22T08:00:14+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2018-02-22T08:24:09+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.tarluz.com\/wp-content\/uploads\/2018\/02\/NON_CONTACT-MPO-Mechanisim.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"900\" \/>\n\t<meta property=\"og:image:height\" content=\"508\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"TARLUZ.COM\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"TARLUZ.COM\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minuto\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.tarluz.com\\\/es\\\/data-center\\\/introduction-non-contact-mpo-fiber-connectors\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.tarluz.com\\\/es\\\/data-center\\\/introduction-non-contact-mpo-fiber-connectors\\\/\"},\"author\":{\"name\":\"TARLUZ.COM\",\"@id\":\"https:\\\/\\\/www.tarluz.com\\\/es\\\/#\\\/schema\\\/person\\\/5740f1b7210de5d651317604459f2fb1\"},\"headline\":\"Introduction to Non-contact MPO Fiber Connectors\",\"datePublished\":\"2018-02-22T08:00:14+00:00\",\"dateModified\":\"2018-02-22T08:24:09+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.tarluz.com\\\/es\\\/data-center\\\/introduction-non-contact-mpo-fiber-connectors\\\/\"},\"wordCount\":177,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.tarluz.com\\\/es\\\/data-center\\\/introduction-non-contact-mpo-fiber-connectors\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.tarluz.com\\\/wp-content\\\/uploads\\\/2018\\\/02\\\/NON_CONTACT-MPO-Mechanisim.jpg\",\"articleSection\":[\"Data Center\"],\"inLanguage\":\"es\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.tarluz.com\\\/es\\\/data-center\\\/introduction-non-contact-mpo-fiber-connectors\\\/\",\"url\":\"https:\\\/\\\/www.tarluz.com\\\/es\\\/data-center\\\/introduction-non-contact-mpo-fiber-connectors\\\/\",\"name\":\"Introduction to Non-contact MPO Fiber Connectors - TARLUZ - FIBER OPTIC SUPPLIERS\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.tarluz.com\\\/es\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.tarluz.com\\\/es\\\/data-center\\\/introduction-non-contact-mpo-fiber-connectors\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.tarluz.com\\\/es\\\/data-center\\\/introduction-non-contact-mpo-fiber-connectors\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.tarluz.com\\\/wp-content\\\/uploads\\\/2018\\\/02\\\/NON_CONTACT-MPO-Mechanisim.jpg\",\"datePublished\":\"2018-02-22T08:00:14+00:00\",\"dateModified\":\"2018-02-22T08:24:09+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/www.tarluz.com\\\/es\\\/#\\\/schema\\\/person\\\/5740f1b7210de5d651317604459f2fb1\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.tarluz.com\\\/es\\\/data-center\\\/introduction-non-contact-mpo-fiber-connectors\\\/#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.tarluz.com\\\/es\\\/data-center\\\/introduction-non-contact-mpo-fiber-connectors\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/www.tarluz.com\\\/es\\\/data-center\\\/introduction-non-contact-mpo-fiber-connectors\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.tarluz.com\\\/wp-content\\\/uploads\\\/2018\\\/02\\\/NON_CONTACT-MPO-Mechanisim.jpg\",\"contentUrl\":\"https:\\\/\\\/www.tarluz.com\\\/wp-content\\\/uploads\\\/2018\\\/02\\\/NON_CONTACT-MPO-Mechanisim.jpg\",\"width\":900,\"height\":508},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.tarluz.com\\\/es\\\/data-center\\\/introduction-non-contact-mpo-fiber-connectors\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.tarluz.com\\\/es\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Introduction to Non-contact MPO Fiber Connectors\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.tarluz.com\\\/es\\\/#website\",\"url\":\"https:\\\/\\\/www.tarluz.com\\\/es\\\/\",\"name\":\"TARLUZ - FIBER OPTIC SUPPLIERS\",\"description\":\"DEDICATED IN FIBER OPTIC INDUSTRY\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.tarluz.com\\\/es\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"es\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.tarluz.com\\\/es\\\/#\\\/schema\\\/person\\\/5740f1b7210de5d651317604459f2fb1\",\"name\":\"TARLUZ.COM\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/6e1d411095ca6ac0a50a32b0e09d4e99f1d22d747cb3e84f95fe301bdc28d113?s=96&d=blank&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/6e1d411095ca6ac0a50a32b0e09d4e99f1d22d747cb3e84f95fe301bdc28d113?s=96&d=blank&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/6e1d411095ca6ac0a50a32b0e09d4e99f1d22d747cb3e84f95fe301bdc28d113?s=96&d=blank&r=g\",\"caption\":\"TARLUZ.COM\"},\"url\":\"https:\\\/\\\/www.tarluz.com\\\/es\\\/author\\\/admin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Introduction to Non-contact MPO Fiber Connectors - TARLUZ - FIBER OPTIC SUPPLIERS","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.tarluz.com\/es\/data-center\/introduction-non-contact-mpo-fiber-connectors\/","og_locale":"es_ES","og_type":"article","og_title":"Introduction to Non-contact MPO Fiber Connectors","og_description":"The Non-Contact MPO fiber connector (NC-MPO) invented by Arrayed Fiberoptics, it might be the next generation multi-fiber optical connector for data center project, where there is no contact between fiber surfaces. There are two key elements in the NC-MPO connector, first, the fiber surface is recessed, and second, the fiber surface has an anti-reflection coating. [&hellip;]","og_url":"https:\/\/www.tarluz.com\/es\/data-center\/introduction-non-contact-mpo-fiber-connectors\/","og_site_name":"TARLUZ - FIBER OPTIC SUPPLIERS","article_published_time":"2018-02-22T08:00:14+00:00","article_modified_time":"2018-02-22T08:24:09+00:00","og_image":[{"width":900,"height":508,"url":"https:\/\/www.tarluz.com\/wp-content\/uploads\/2018\/02\/NON_CONTACT-MPO-Mechanisim.jpg","type":"image\/jpeg"}],"author":"TARLUZ.COM","twitter_card":"summary_large_image","twitter_misc":{"Escrito por":"TARLUZ.COM","Tiempo de lectura":"1 minuto"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.tarluz.com\/es\/data-center\/introduction-non-contact-mpo-fiber-connectors\/#article","isPartOf":{"@id":"https:\/\/www.tarluz.com\/es\/data-center\/introduction-non-contact-mpo-fiber-connectors\/"},"author":{"name":"TARLUZ.COM","@id":"https:\/\/www.tarluz.com\/es\/#\/schema\/person\/5740f1b7210de5d651317604459f2fb1"},"headline":"Introduction to Non-contact MPO Fiber Connectors","datePublished":"2018-02-22T08:00:14+00:00","dateModified":"2018-02-22T08:24:09+00:00","mainEntityOfPage":{"@id":"https:\/\/www.tarluz.com\/es\/data-center\/introduction-non-contact-mpo-fiber-connectors\/"},"wordCount":177,"commentCount":0,"image":{"@id":"https:\/\/www.tarluz.com\/es\/data-center\/introduction-non-contact-mpo-fiber-connectors\/#primaryimage"},"thumbnailUrl":"https:\/\/www.tarluz.com\/wp-content\/uploads\/2018\/02\/NON_CONTACT-MPO-Mechanisim.jpg","articleSection":["Data Center"],"inLanguage":"es"},{"@type":"WebPage","@id":"https:\/\/www.tarluz.com\/es\/data-center\/introduction-non-contact-mpo-fiber-connectors\/","url":"https:\/\/www.tarluz.com\/es\/data-center\/introduction-non-contact-mpo-fiber-connectors\/","name":"Introduction to Non-contact MPO Fiber Connectors - TARLUZ - FIBER OPTIC SUPPLIERS","isPartOf":{"@id":"https:\/\/www.tarluz.com\/es\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.tarluz.com\/es\/data-center\/introduction-non-contact-mpo-fiber-connectors\/#primaryimage"},"image":{"@id":"https:\/\/www.tarluz.com\/es\/data-center\/introduction-non-contact-mpo-fiber-connectors\/#primaryimage"},"thumbnailUrl":"https:\/\/www.tarluz.com\/wp-content\/uploads\/2018\/02\/NON_CONTACT-MPO-Mechanisim.jpg","datePublished":"2018-02-22T08:00:14+00:00","dateModified":"2018-02-22T08:24:09+00:00","author":{"@id":"https:\/\/www.tarluz.com\/es\/#\/schema\/person\/5740f1b7210de5d651317604459f2fb1"},"breadcrumb":{"@id":"https:\/\/www.tarluz.com\/es\/data-center\/introduction-non-contact-mpo-fiber-connectors\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.tarluz.com\/es\/data-center\/introduction-non-contact-mpo-fiber-connectors\/"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.tarluz.com\/es\/data-center\/introduction-non-contact-mpo-fiber-connectors\/#primaryimage","url":"https:\/\/www.tarluz.com\/wp-content\/uploads\/2018\/02\/NON_CONTACT-MPO-Mechanisim.jpg","contentUrl":"https:\/\/www.tarluz.com\/wp-content\/uploads\/2018\/02\/NON_CONTACT-MPO-Mechanisim.jpg","width":900,"height":508},{"@type":"BreadcrumbList","@id":"https:\/\/www.tarluz.com\/es\/data-center\/introduction-non-contact-mpo-fiber-connectors\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.tarluz.com\/es\/"},{"@type":"ListItem","position":2,"name":"Introduction to Non-contact MPO Fiber Connectors"}]},{"@type":"WebSite","@id":"https:\/\/www.tarluz.com\/es\/#website","url":"https:\/\/www.tarluz.com\/es\/","name":"TARLUZ - FIBER OPTIC SUPPLIERS","description":"DEDICATED IN FIBER OPTIC INDUSTRY","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.tarluz.com\/es\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":"Person","@id":"https:\/\/www.tarluz.com\/es\/#\/schema\/person\/5740f1b7210de5d651317604459f2fb1","name":"TARLUZ.COM","image":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/secure.gravatar.com\/avatar\/6e1d411095ca6ac0a50a32b0e09d4e99f1d22d747cb3e84f95fe301bdc28d113?s=96&d=blank&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/6e1d411095ca6ac0a50a32b0e09d4e99f1d22d747cb3e84f95fe301bdc28d113?s=96&d=blank&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/6e1d411095ca6ac0a50a32b0e09d4e99f1d22d747cb3e84f95fe301bdc28d113?s=96&d=blank&r=g","caption":"TARLUZ.COM"},"url":"https:\/\/www.tarluz.com\/es\/author\/admin\/"}]}},"_links":{"self":[{"href":"https:\/\/www.tarluz.com\/es\/wp-json\/wp\/v2\/posts\/8536","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.tarluz.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.tarluz.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.tarluz.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.tarluz.com\/es\/wp-json\/wp\/v2\/comments?post=8536"}],"version-history":[{"count":9,"href":"https:\/\/www.tarluz.com\/es\/wp-json\/wp\/v2\/posts\/8536\/revisions"}],"predecessor-version":[{"id":8552,"href":"https:\/\/www.tarluz.com\/es\/wp-json\/wp\/v2\/posts\/8536\/revisions\/8552"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.tarluz.com\/es\/wp-json\/wp\/v2\/media\/8547"}],"wp:attachment":[{"href":"https:\/\/www.tarluz.com\/es\/wp-json\/wp\/v2\/media?parent=8536"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.tarluz.com\/es\/wp-json\/wp\/v2\/categories?post=8536"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.tarluz.com\/es\/wp-json\/wp\/v2\/tags?post=8536"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}