QSFP+ Transceiver Modules Installation Guide

Thanks for choose TARLUZ QSFP+ Transceivers, The transceivers may compatible with different network devices from different venders, TARLUZ could offer Generic and compatible QSFP+ Transceivers, CAUTION: When installing or removing a transceiver module, avoid touching the golden plating on the transceiver module with a bare hand. Do not remove the dust plug from a transceiver […]

Data Center

MPO & MTP kontakten

MPO är en förkortning av en industriakronym ”Multi-fiber Push On”. MPO-kontakten är i grunden en flerfiberkontakt och är definierad i två dokument: IEC-61754-7 (den internationella standarden för MPO-kontakten) och EIA/TIA-604-5 (också känt som FOCIS 5, detta är i första hand USA-standard). MPO-kontakten är baserad på MT-ferrul-MTP-kontakten (visas i bilden ovan) den kan utföra stabila högprestanda […]

Data Center

Polaritetens betydelse för MPO/MTP

MPO/MTP är en flexibel, hållbar samt skalbar teknisk lösning med hög densitet, och är samtidigt en av de mest relevanta teknikerna för att migrera system över till 40 & 100G Ethernet. En av stötestenarna som en nätverksdesigner behöver tänka på, är hur man försäkrar sig i att rätt polaritet på sändande/mottagande fibrer uppnås från start […]

Data Center

Copper Classes & Categories

“Class” means something completely different than “category”. The class (or category link in American English) always applies to the installed link, the category as such applies only to one single component, e.g. the cable or the outlet; the component is tested and verified by either the labs of the manufacturer or independent verification labs.   […]

Copper Network, Data Center

TIA-942-B Data Center Cabling Standard is updated

The Telecommunications Industry Association TR-42 Telecommunications Cabling Systems Engineering Committee approved the TIA-942-B Data Center Cabling Standard. To help data centers address current and future needs, the updated standard includes several substantial changes from the previous version. TIA represents the companies that supply high-tech communications networks and is a global leader in developing industry standards […]

Data Center

Data Center Design for 40G/100G Network

1G and 10G data rates are not adequate to meet the future needs of high-bandwidth appli- cations. The requirement for higher data rates is being driven by many factors. Switching and routing, virtualization, convergence and high-performance computing environments are examples of where these higher network speeds will be required within the data center environment. Additionally, […]

Data Center

MTP® Connector cleaning instructions

A. Clean connector by MTP cleaner Before you clean the MTP connector, please inspect it first, if it is clean, no need to clean it. Insert the the MTP Cleaner into the adaptor where the connector is mated Rotate the tape feeder wheel as indicated on the cleaner Inspect the connector with 200 x microscope […]

Data Center

Conservando la polaridad en los sistemas MPO/MTP

Los sistemas troncales montados en fábrica, con conectores multifibra MPO, son utilizados de preferencia y de forma creciente para los despliegues de sistemas ópticos de cableado; sobre todo en áreas de alta concentración, tales como los centros de datos. Para poder mantener unas vías bi-direccionales de transmisión, el sistema debe proporcionar una polaridad correcta que […]

Data Center

Introduction to OM5 Fiber

ISO/IEC decided to name WBMMF Wideband Multimode Fiber as OM5 in Oct. 2016, this decision was made by ISO/IEC Joint Technical Committee 1 (JTC 1)/Subcommittee 25 (SC 25) Interconnection of Information Technology Equipment. At a spring 2016 meeting of JTC 1/SC 25’s Working Group 3 – Customer Premises Cabling – the working group was unable […]